20-KVA MONO PHASE REGULATOR


SINGLE-PHASE STATIC REGULATOR

Single-phase static regulators are advanced technology regulators with high regulation speed and full protection systems. They provide a safe and stable output voltage in places where the mains voltage is unstable and for highly sensitive devices. Their biggest advantage over other regulators is their high-speed response to sudden voltage fluctuations. They are manufactured with the capacity to operate smoothly even under full load and in cases where the voltage value changes instantly. Since there are no moving parts inside, they are long-lasting and maintenance-free.

1 kVA – 80 kVA

100% compatibility with all single-phase devices

Operation with 65 V AC input

Wide correction range (45 V – 300 V AC)

20 ms voltage correction speed

Control and protection unit with microprocessor control

Real static structure thanks to thyristor and SMPS technology

Overcurrent protection and voltage protection (Standard)

Short circuit protection (Standard)

Real temperature control and temperature protection (Standard)

Necessary cooling with smart fan (Standard)

Manual By-Pass and Automatic By-Pass

High efficiency and quiet operation

1 piece 4x20 LCD (Standard)

Automatically recorded on the LCD: all errors, operating time, highest–lowest voltage seen, highest current load, high temperature, consumption counter, design number, step count, software date and number, warranty number

High-quality, ergonomic structure, compact dimensions, easy portability

ISO 9001:2008


 


INPUT PARAMETERS

Input Connection Phase Number: 1 Phase
Continuous Operating Time at Full Load 0...105%: Continuous 24/7
Possible Input Voltage Range: >0 V…450 V<
Supply Voltage Operating Range: >65 V….290 V<
Supply Protection Entry Voltage Range: <45 V…..300 V>
Input Correction Range: >90 V…..290 V<
Operating Frequency: >47 V…..63 V< — 50 Hz
Correction Speed = Second / Frequency:

Frequency = 50 → 20 ms

Frequency = 60 → 16.66 ms
Switching: Thyristor-Controlled Static Regulator

ENVIRONMENTAL CONDITIONS

Input Connection Phase Number: 1 Phase
Relative Humidity: < 96% (Non-condensing)
Operating Altitude: < 3,000 meters (3 km)
Protection Class: IP21
Operating Temperature: 0 > -40 °C < +55 °C

LCD DISPLAY

Input voltage, output load percentage, regulator status and fault information, overload warning, overheat warning, input fault warning, output fault warning, maximum and minimum input voltage and current after last start, countdown time, multi-display.

Operating Temperature: 0 > -40 °C < +55 °C — Available

DISPLAY PAGING AND INFORMATION MONITORING

Software version, software date, static stage count, module count, warranty number, fault monitoring, error count, error cause, total operating hours.
Selectable via Menu Button: Yes

Adjustment of All Parameters: Via Menu Button — Available
Minimum Fault-Free Operating Time: 61,320 hours
Circular Logic Fault Monitoring Count: 65,535 units
Circular Logic Fault Monitoring Duration: 7 years
Fault Storage in EEPROM Internal Memory: 1024 bit